Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/07/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 10/7/26: add anchor bolts 32"o.c., add shot pins at marked locations, add nails to loose roof panel at marked locations, and add nails to exterior sheathing throughout-over penetrated nailing (do not over penetrate more than 1/16") and nails can't be closer than 3/8" from edges/joints, provide ladder to inspect parapets. | |
| 10/08/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 10/08/2026 All corrections made. Verified parapet and crickets on roof. |