Permit: TC-RES-1223-10164

Parcel: 106121750


Addresses:

1621 W WINDSOR ST

Inspection Status: Not Ready

Inspection History: COT - RSME - Mechanical Final 

Date Description Inspector Results Comments
03/11/2024 COT - RSME - Mechanical Final  Not Ready 3/11/24: not ready
06/26/2024 COT - RSME - Mechanical Final  Not Ready
07/02/2024 COT - RSME - Mechanical Final  Re-inspection required 3/11/24: not ready
7/2/24: no access to panel, multiple circuits off, secure gas line at back porch, water hammer arrestor missing at dishwasher, water heater missing fuses, no ladder for roof access. STOPPED INSPECTION NOT READY PLEASE UNLOCK MAIN PANEL.
07/03/2024 COT - RSME - Mechanical Final  Re-inspection required 3/11/24: not ready
7/2/24: no access to panel, multiple circuits off, secure gas line at back porch, water hammer arrestor missing at dishwasher, water heater missing fuses, no ladder for roof access. STOPPED INSPECTION NOT READY PLEASE UNLOCK MAIN PANEL.
7/3/24: exterior receptacles not GFCI, insulate and seal hose bib at front of house, panel schedule incomplete, 2 circuits required at kitchen, insulate hose bib at back porch, A/C drain must terminate 6" above grade, exterior plastic piping must be UV coated, T&P must terminate 6" above grade, water hammer arrestor missing at refrigerant, dryer vent exhaust must have screen removed from T-top, smoke detector missing outside bedroom, SWG METER needs clearance of 3' from all openings, storage unit at backyard not on site plan.
07/10/2024 COT - RSME - Mechanical Final  Passed