Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/27/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Partial Pass | Partial pass. All underground plumbing and vent pipes going through the roof under pressure. (DWV). Approved. Okay to backfill. Shading required. 2/27/2024 | |
| 03/11/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | Partial pass. All underground plumbing and vent pipes going through the roof under pressure. (DWV). Approved. Okay to backfill. Shading required. 2/27/2024 3/11/23: revision needed for changes at kitchen and bathroom on west end of house. Seal all penetrations through top plate, seal all penetrations through vapor barrier, wire size not per plan in multiple rooms, No gas lines installed at time of inspection. fan fixtures cannot be supported by drywall screws. A/C registers need blocking at 3 sides. STOPPED INSPECTION MORE ITEMS MAY BE ADDED |
|
| 03/13/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Partial Pass | Partial pass. All underground plumbing and vent pipes going through the roof under pressure. (DWV). Approved. Okay to backfill. Shading required. 2/27/2024 3/11/23: revision needed for changes at kitchen and bathroom on west end of house. Seal all penetrations through top plate, seal all penetrations through vapor. No gas lines installed at time of inspection. fan fixtures cannot be supported by drywall screws. STOPPED INSPECTION MORE ITEMS MAY BE ADDED 3/13/24: corrections made throughout home. Ok to insulate and drywall (bathroom cannot be insulated or drywalled until revisions are made). |
|
| 06/26/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Not Ready | ||
| 07/02/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed |