Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - RSBU - Masonry Pregrout
Permit Number - TC-RES-1223-10106
Inspection Description - COT - RSBU - Masonry Pregrout
Inspection Status - Partial Pass
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/22/2024 | COT - RSBU - Masonry Pregrout | Partial Pass | 5/22/24: reinforcement per plan at first 4' lift ok to proceed. (Main house only) | |
05/30/2024 | COT - RSBU - Masonry Pregrout | Partial Pass | CMU walls of structure at 4’ - 9’ 4”. Ok to grout progress areas. Patio walls at 52” - 60”; ensure all rebar is in place (NE and NW corners). Ok to grout progress areas. | |
06/11/2024 | COT - RSBU - Masonry Pregrout | Partial Pass | North portion of building at 8’ - 12’; South portion of building at 8’ - 12’8”. Ok to place grout in progress areas. | |
06/18/2024 | COT - RSBU - Masonry Pregrout | Partial Pass | CMU Walls at Northwest, North, and Northeast sections of interior walls are 18’ 8”. OK to grout progress areas. | |
06/25/2024 | COT - RSBU - Masonry Pregrout | Partial Pass | South half of structure is topped out at 22’; North portion of structure is at 16’. Ok to grout progress areas. | |
08/12/2024 | COT - RSBU - Masonry Pregrout | Passed |