Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSPL - Sewer
Permit Number - TC-RES-1223-10106
Inspection Description - COT - RSPL - Sewer
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/04/2024 | COT - RSPL - Sewer | Re-inspection required | 4/4/24: 360 degree clearance around joints must be exposed for proper inspection, trench is wet in multiple locations could not verify source, water service and building sewer must be separated per IRC 2018 P2906.4.1, plumbing underground not per plan at south west corner of building. Water line must be 12" deep. | |
04/05/2024 | COT - RSPL - Sewer | Passed | ||
04/08/2024 | COT - RSPL - Sewer | Passed | Okay to backfill. Shading is required. 4/8/2024 | |
COT - RSPL - Sewer | Passed |