Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Sewer 

Permit Number - TC-RES-1223-10106

Inspection Description - COT - RSPL - Sewer 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
04/04/2024 COT - RSPL - Sewer  Re-inspection required 4/4/24: 360 degree clearance around joints must be exposed for proper inspection, trench is wet in multiple locations could not verify source, water service and building sewer must be separated per IRC 2018 P2906.4.1, plumbing underground not per plan at south west corner of building. Water line must be 12" deep.
04/05/2024 COT - RSPL - Sewer  Passed
04/08/2024 COT - RSPL - Sewer  Passed Okay to backfill. Shading is required. 4/8/2024
COT - RSPL - Sewer  Passed