Inspection Status: Re-inspection required
Inspection History: COT - RSPL - Yard Water Line
Permit Number - TC-RES-1223-10106
Inspection Description - COT - RSPL - Yard Water Line
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/04/2024 | COT - RSPL - Yard Water Line | Re-inspection required | 4/4/24: 360 degree clearance around joints must be exposed for proper inspection, trench is wet in multiple locations could not verify source, water service and building sewer must be separated per IRC 2018 P2906.4.1, plumbing underground not per plan at south west corner of building. Water line must be 12" deep. | |
04/05/2024 | COT - RSPL - Yard Water Line | Re-inspection required | Water line needs to be separated from the sewer line due to cross contamination. 5' separation on 12" elevated above sewer line. 4/5/2024 | |
04/08/2024 | COT - RSPL - Yard Water Line | Passed | Okay to backfill. Shading is required. 4/8/2024 | |
COT - RSPL - Yard Water Line | Passed | |||
COT - RSPL - Yard Water Line | Passed |