Permit: TC-RES-1223-10015

Parcel: 120091300


Addresses:

426 E MICHIGAN DR

Inspection Status: Re-inspection required

Inspection History: COT - RSEL - Electrical Final 

Date Description Inspector Results Comments
03/17/2025 COT - RSEL - Electrical Final  Re-inspection required 17 Mar 25
1. Exterior outlets need to WR rated, to include the hvac service outlet on rooftop.
2. Need metal collar on water heater ceiling penetration
3. Water heater t/p discharge needs to terminate no more than 6 inches from the ground.
4. Dryer exhaust needs to have backdraft damper, remove screen.
5. Laundry is not on GFCI circuit.
6. Range needs anti-tip bracket.
7. Hose bibs needs to be anti-siphon.
03/24/2025 COT - RSEL - Electrical Final  Passed 24 March 25
Pass