Parcel: 12607068B


Addresses:

3938 E ELMWOOD ST


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Permit Number - TC-RES-1223-10006

Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
01/07/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 1-7-25,fire foam missing at garage near water heater and at laundry room, properly secure pex line to backing in each bathroom, secure pex line at laundry room and secure gas line located in same area, pex lines within 12 inches of can lights must be insulated or blocked. Gas pressure test must be at 15psi for a minimum of 10 minutes.
01/08/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Ok to insulate and Sheetrock throughout.
10/28/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready Will reschedule when intermediates are ready.
12/19/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready Work incomplete.
12/26/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required Outdoor light box not properly bonded. Receptacles in bedroom 3 exceeding 12’ spacing. Missing smoke detectors throughout. Add backing to secure pex line in place at tub. Gas pressure test is less than 15psi. Add support for gas line in kitchen area. Receptacles at kitchen stand not made up. Add backing for 4 gang box. Add blocking to register in bathroom at bedroom #2. Provide 18” of copper at water heater. Seal Al exterior penetrations. Secure vertical vent pipes. Secure duct in garage area. 12/26/2024