Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSMH - Mobile/Mod Home FinalĀ 

Date Description Inspector Results Comments
03/07/2024 COT - RSMH - Mobile/Mod Home FinalĀ  Re-inspection required 3/7/24: water hammer arrestors required at (refrigerator,dishwasher,laundry room), GFCI receptacles required at laundry room. Receptacles on exterior of mobile home must be WR. Exterior plastic piping must be UV protected, properly secure electrical whips at A/C unit, GFCI receptacles required under kitchen sink