Inspection Status: Re-inspection required

Inspection History: COT - RSMH - Mobile/Mod Home Final 

Permit Number - TC-RES-1222-01610

Inspection Description - COT - RSMH - Mobile/Mod Home Final 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
03/07/2024 COT - RSMH - Mobile/Mod Home Final  Re-inspection required 3/7/24: water hammer arrestors required at (refrigerator,dishwasher,laundry room), GFCI receptacles required at laundry room. Receptacles on exterior of mobile home must be WR. Exterior plastic piping must be UV protected, properly secure electrical whips at A/C unit, GFCI receptacles required under kitchen sink