Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/13/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 01/13/25 Partial pass; missing windows; missing a few anchor bolts locations are marked on the sill plates. Blocking needed, on east wall. |
|
| 04/15/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Add blocking to seams at osb sheathing. Follow the 6"x12" pattern at sheathing. Provide lateral bracing and add h25 at bearing points where marked on truss calc. Provide window in master bedroom for means of egress. Provide pressure seal plates along with pins to hold in place. Add anchor bolts where there has been a break in the plate no more than 12" away. 4/15/2025 | |
| 07/11/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Not Ready | ||
| 08/01/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Not Ready | 8-1-25: not ready. | |
| 12/09/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Partial Pass |