Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSEL - Electrical Final
Permit Number - TC-RES-1222-01381
Inspection Description - COT - RSEL - Electrical Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/23/2024 | COT - RSEL - Electrical Final | Re-inspection required | 5/23/24: Arc-fault breaker required at AZ room receptacle, water hammer arrestor required at laundry, GFCI required at laundry, properly insulate hot water lines, gas bond required, refrigerant lines must be coated for UV protection, properly secure electrical whip at mini split, carbon monoxide/smoke detectors required. | |
05/29/2024 | COT - RSEL - Electrical Final | Passed |