Inspection Status: Re-inspection required

Inspection History: COT - RSEL - Electrical Final 

Permit Number - TC-RES-1222-01381

Inspection Description - COT - RSEL - Electrical Final 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
05/23/2024 COT - RSEL - Electrical Final  Re-inspection required 5/23/24: Arc-fault breaker required at AZ room receptacle, water hammer arrestor required at laundry, GFCI required at laundry, properly insulate hot water lines, gas bond required, refrigerant lines must be coated for UV protection, properly secure electrical whip at mini split, carbon monoxide/smoke detectors required.
05/29/2024 COT - RSEL - Electrical Final  Passed