Inspection History Details
Inspection Status: Re-inspection required
Inspection History: RSBU - Building Final
Permit Number - TC-RES-1222-01381
Inspection Description - RSBU - Building Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/23/2024 | RSBU - Building Final | Re-inspection required | 5/23/24: Arc-fault breaker required at AZ room receptacle, water hammer arrestor required at laundry, GFCI required at laundry, properly insulate hot water lines, gas bond required, refrigerant lines must be coated for UV protection, properly secure electrical whip at mini split, carbon monoxide/smoke detectors required. | |
05/29/2024 | RSBU - Building Final | Passed |