Permit: TC-RES-1222-01248

Parcel: 136350660


Addresses:

1522 S RENEE PL

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
06/20/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 6/20/23: Wall Brace schedule missing Anchor bolts ( 32" O.C) and Anchor bolt missing 12" from end of sill plate. Sheathing schedule needs to be followed throughout wall brace schedule. (WB-1: 1/2" PLY SHEATHING WITH 8d NAILS AT 6" O.C. AT EDGES AND 12" OC. AT FIELD. BLOCK ALL PLYWOOD EDGES. SILL PLATE ATTACHED WITH 1/2" ANCHOR BOLT @ 32" O.C. MAX. ALL EXTERIOR IS IN SHEAR). Plans need to be revised (state no work to be done on north side of house) but new joist were installed throughout the entire house.
08/09/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed