Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: RSBU - Building Progress
Permit Number - TC-RES-1222-01229
Inspection Description - RSBU - Building Progress
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/26/2024 | RSBU - Building Progress | Passed | Base plates are secured to concrete floor with shot pins, poured in place bolts or titan bolts. Plywood sheathing is properly secured to studs per plan requirements for shear walls. Okay to proceed with dry-in for stucco work. Roof trusses are properly secured to top plate with nails and H2.5 clips. Plywood sheathing is nailed to roof trusses per plan and code requirements. Okay to proceed with top out of plumbing and rough-in of mechanical and electrical. |