Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 13634744A

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Preslab  

Permit Number - TC-RES-1222-01229

Inspection Description - COT - RSBU - Preslab  

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
02/15/2024 COT - RSBU - Preslab   Re-inspection required 2/15/24: per approved plans set back on north side of home is not correct. Shower boxes need fill
02/21/2024 COT - RSBU - Preslab   Re-inspection required 2/20/24:per approved plans set back on north side of home is not correct
04/05/2024 COT - RSBU - Preslab   Passed 4/5/24: Setback is 10' from property line on north side of lot. Concrete forms are in place, footings are dug per plans, rebar reinforcement is installed per plans, and 20' piece of rebar is bent and connected to the bottom rebar reinforcement of footing for a Ufer ground. Okay to proceed with concrete pour.