Parcel: 13634744A

Inspection Status: Re-inspection required

Inspection History: COT - RSEL - Grounding/Bonding 

Permit Number - TC-RES-1222-01229

Inspection Description - COT - RSEL - Grounding/Bonding 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
02/21/2024 COT - RSEL - Grounding/Bonding  Re-inspection required 2/20/24:per approved plans set back on north side of home is not correct
04/05/2024 COT - RSEL - Grounding/Bonding  Passed 4/5/24: Setback is 10' from property line on north side of lot. Concrete forms are in place, footings are dug per plans, rebar reinforcement is installed per plans, and 20' piece of rebar is bent and connected to the bottom rebar reinforcement of footing for a Ufer ground. Okay to proceed with concrete pour.