Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Plumbing Final 

Date Description Inspector Results Comments
01/05/2026 COT - RSPL - Plumbing Final  Re-inspection required 1/5/26: Insulation required R-3 at exterior hose bib and must be coated for UV protection, Water heater was replaced and was not part of scope of work, all 3/4 piping at water heater must be insulated, b-vent must be properly installed at water heater, T&P valve must be properly installed, properly secure supply line water closet and all areas that are not properly supported, r-3 insulation required at hose bib on exterior, properly secure supply lines at kitchen sink, properly support all supply lines throughout home.
11/07/2025 COT - RSPL - Plumbing Final  Not Ready
11/14/2025 COT - RSPL - Plumbing Final  Passed