Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSEL - Outdoor Lighting
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/26/2026 | COT - RSEL - Outdoor Lighting | Re-inspection required | 1. Missing Combination smoke/co detector in immediate vicinity of bedrooms 2. Kitchen sink and dishwasher incomplete 3. Missing 1/2 inch threshold per COT and Pima country inclusive home design 4. Terminate dryer exhaust and add backdraft damper 5. Terminate water heater t/p line within 2-6 inch of earth 6. Outdoor lighting needs to be fully shielded or full cut off per 2012 Pima county light pollution ordinance. 7. Garage door needs to be self closing and self latching. |
|
| 08/31/2026 | COT - RSEL - Outdoor Lighting | Passed |