Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSME - Mechanical Final
Permit Number - TC-RES-1124-06761
Inspection Description - COT - RSME - Mechanical Final
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/21/2025 | COT - RSME - Mechanical Final | Re-inspection required | 5/20/25 1. Kitchen requires 2 GFCI circuits. 2. Loose outlets in kitchen and dining room. 3. Water hammer arrestors needed at washer and fridge water inlet. 4. Missing receptacles in bedrooms. 5. All exterior outlets must be WR rated. 6. Thermostat too high, 48" max. |
|
| 06/06/2025 | COT - RSME - Mechanical Final | Not Ready | No access for inspection | |
| 06/06/2025 | COT - RSME - Mechanical Final | Not Ready | no access for inspection | |
| 08/06/2025 | COT - RSME - Mechanical Final | Re-inspection required | 8.6.25 No corrections were made. Make corrections per previous notes. |