Permit: TC-RES-1124-06660

Parcel: 132180790


Addresses:

4874 S MOUNTAIN AV

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
02/17/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 2-17-26: add anchor bolts 32" o.c. Maximum, change headers to 2x8's, add nails to exterior sheathing along edges between 3/8" -1/2" maximum & add nails edges/in the field per plans, add top plates at south and north walls, plans call for 2x6's at 16" o.c.- either install per plans Or submit a revision to the city for review for 2x6's at 24" o.c...STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE ADDED.
02/23/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Partial Pass Partial pass. Corrections were made. No additional items needed. Pending interior framing. 2/23/2026