Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/03/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 5/3/23: Repair hole in kitchen block wall, north block wall required to be fully grout under new GLB to the floor, open chase's into the attic space in all rooms,vents are dry, register flanges are not blocked and are not flush to the wall, flanges are too small for register to attach to, remove covers to all metal elect boxes. | |
| 05/10/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 5/3/23: Repair hole in kitchen block wall, north block wall required to be fully grout under new GLB to the floor, open chase's into the attic space in all rooms,vents are dry, register flanges are not blocked and are not flush to the wall, flanges are too small for register to attach to, remove covers to all metal elect boxes. 5/10/23: fire-block top of chase between bathroom and kitchen, fill new vent with water |
|
| 05/11/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed |