Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 133522020


Addresses:

180 N FENCELINE DR


Inspection Status: Partial Pass

Inspection History: COT - RSPL - Plumbing Final 

Permit Number - TC-RES-1025-05302

Inspection Description - COT - RSPL - Plumbing Final 

Inspection Status - Partial Pass

Date Description Inspector Results Comments
11/04/2025 COT - RSPL - Plumbing Final  Partial Pass 1. Water line in living room needs to be supported.
2. Support hot and cold water lines for mixing valve in downstairs bathroom.
3. Hose bibs needs to be anti-siphon.
4. Water hammer arrestors needed at dishwasher, and ice maker.
11/05/2025 COT - RSPL - Plumbing Final  Passed