Inspection Status: Passed

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
11/28/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 11.28.2025
Approved per plan. Added firefoam at top plate penetrations and arranged sequence of receptacles 6' from doors and 12' max spacing between receptacles per E3901.2.1 of the 2018 IRC. Okay to proceed with construction.