Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
10/07/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 10/7/26: only inspected new addition area: add shot pins to marked locations, add 1/2" anchor bolt on each side of a sill plate splice within 12", replace 7/16" anchor bolts with 1/2", reattach h-25's with nails per manufactured specifications, add nails to exterior sheathing 6" o.c. Along edges/splices and no closer than 3/8" from joints.
10/08/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 10/08/2026
Corrections made.