Permit: TC-RES-1025-04892

Parcel: 118050500

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
05/11/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 05/11/2026
Add nails on exterior panels that are over-driven or missing as marked and throughout - need to be flush to OSB surface with 6" on edges and 12" in field on center. Add anchor bolts at marked locations 48" on center and at splices within 12" of sill plate edges with a 3.5" buffer. Add cs16 strap to large splice to top plate for post and at corner where top doesn't go through. Verified existing rafters 24" o.c. with hangers and h2.5 clips.
05/18/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 5/18/2026
Corrections made.