Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSEL - Electrical Final
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/21/2026 | COT - RSEL - Electrical Final | Re-inspection required | 5-21-26: called poc and left voicemail at 721am advising I was on my way to home for inspections. Arrived on site at 730am, rang door bell but didn't receive an answer. After waiting 10 minutes, I left. Please reschedule inspections at your convenience. | |
| 05/26/2026 | COT - RSEL - Electrical Final | Re-inspection required | 5-26-26: install a return or install a louvered transfer grill with 30 square inches of net free area above bedroom door, install frosted exterior light fixtures, move smoke detector a minimum of 3' from louvered transfer grill, missing knockout at main panel together with a arch-fault breaker for new bedroom. Note: Pending letter and city approval showing studs at 24” o.c.. |
|
| 06/02/2026 | COT - RSEL - Electrical Final | Passed | corrections made |