Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-1025-04818

Parcel: 11806108A


Addresses:

1954 W KING AV

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
03/13/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 3-13-26: add additional shot pins at fur out & extend wood strips down to sill plate, add shot pins within 6" at the ends of each plate, add backing for grab bars at restroom-see City of Tucson Inclusive page for installation requirements. Stopped inspection.
03/23/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 3/23/2026 all corrections were made. No additional items found.m