Inspection Status: Not Ready
Inspection History: COT - RSEL - Electrical Final
| Date |
Description |
Inspector |
Results |
Comments |
| 08/18/2026 |
COT - RSEL - Electrical Final |
|
Not Ready |
|
| 10/14/2026 |
COT - RSEL - Electrical Final |
|
Not Ready |
10/14/2026 provide TR receptacles throughout per plan. Provide afci breakers at living spaces. Provide combo afci/gfci breakers at wet locations. Provide two circuits at kitchen and ensure they are gfci protected. Provide gfi at laundry room along with both bathroom receptacles. Provide smoke detectors in bedroom. Ensure outdoor receptacles are WR and gfci protected. |