Permit: TC-RES-1024-06045

Parcel: 124122340


Addresses:

1537 E MANLOVE ST

Inspection Status: Re-inspection required

Inspection History: COT - RSEL - Electrical Final 

Date Description Inspector Results Comments
08/01/2025 COT - RSEL - Electrical Final  Re-inspection required 8.1.25
Missing receptacles at both bedrooms. Receptacles must be present within 6' from door and every 12' thereafter.
Missing at fault breakers at moved sub panel. In addition, any NEW breakers that provide power to circuits at living spaces must be arc fault
Required access to roof
08/13/2025 COT - RSEL - Electrical Final  Passed No electric clearance required.