Permit: TC-RES-1024-06009

Parcel: 138211150


Addresses:

7271 S BOBBI PL

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
07/20/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 7-20-26: not ready-add anchor bolts within 12" at ends of plate and add an anchor bolts at each side of a space within 12", anchor bolts are required at 32" o.c.-see plans for details, missing H25's at each truss, add nails to sheathing at 6" o.c. at splices/joints and 12 o.c. In the field. Stopped inspection-additional items may be noted.
07/21/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 07/21/2026
Corrections made. Walked remaining area.