Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-1024-05999

Parcel: 125010580


Addresses:

2604 E 8TH ST

Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Plumbing Final 

Date Description Inspector Results Comments
05/02/2025 COT - RSPL - Plumbing Final  Re-inspection required Provide hammer arrestor on hot line for dishwasher. Add vacuum breaker at hose bib. Insulate exterior water line. Add Tmp line for water heater. Dialectical fitting has to be in place at point of connection to water heater for dissimilar metals also at flex line. Plans call for 3/4 water lines. 1/2 is in place reducing water pressure. Add seal tight to electrical lines at disconnect. Secure disconnect mc cable. Add gfci receptacles to all wet locations. Re label panel. Receptacle in hall is not working. 5/2/2025
05/19/2025 COT - RSPL - Plumbing Final  Passed