| 08/08/2025 | RSBU - Building Final | Re-inspection required | 8.8.2025 RAMADA WR (weather resistant) electrical receptacle outside needed. Verification of footing depth needed. WORKSHOP Outside water service valves need anti-siphon / vacuum breaker device and insulation on pipes from head to grade. Need brace within 12” from disconnect box line at mini-split compressor outside. Need arc-fault circuit interruptors at receptacles in habitable rooms and hallway or at panel. Plastic pipes outside need painted to protect from UV damage. |