Permit: TC-RES-1023-09066

Parcel: 116150960


Addresses:

1 N TUCSON TE

Inspection Status: Re-inspection required

Inspection History: RSBU - Building Final 

Date Description Inspector Results Comments
08/08/2025 RSBU - Building Final  Re-inspection required 8.8.2025
RAMADA
WR (weather resistant) electrical receptacle outside needed.
Verification of footing depth needed.

WORKSHOP
Outside water service valves need anti-siphon / vacuum breaker device and insulation on pipes from head to grade.
Need brace within 12” from disconnect box line at mini-split compressor outside.
Need arc-fault circuit interruptors at receptacles in habitable rooms and hallway or at panel.
Plastic pipes outside need painted to protect from UV damage.
12/09/2025 RSBU - Building Final  Passed