Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-RES-1023-08925
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/05/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 3/5/25: shear walls not fastened per schedule, hold downs missing at shear walls, expansion bolts required at 2X at doorway from kitchen to hall, framing not per approved plans at sill plate attachment to 2x6 studs. Floor joist not installed per plan.revision required | |
| 03/25/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | All items in previous inspection have been addressed and corrected as per letter from architect.Ok to cover exterior walls. |