Parcel: 11707097A


Addresses:

528 S 3RD AV


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-RES-1023-08925

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
03/05/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 3/5/25: shear walls not fastened per schedule, hold downs missing at shear walls, expansion bolts required at 2X at doorway from kitchen to hall, framing not per approved plans at sill plate attachment to 2x6 studs. Floor joist not installed per plan.revision required
03/25/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed All items in previous inspection have been addressed and corrected as per letter from architect.Ok to cover exterior walls.