Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-1023-08896

Parcel: 11604072A


Addresses:

1901 N WESTRIDGE AV

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
05/29/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required Ensure roof and lath is complete. Add ground screw to metal boxes. Fire foam all top penetrations. Add nails plates to plumbing lines that are less than an 1 1/4" from face of 2x. Add flex line to exhaust fan in bathroom. Secure water line vertically and horizontally along with ABS. Seal all exterior penetrations. 5/29/2025
06/06/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed All corrections were made. 6/6/2025