Permit: TC-RES-1023-08893

Parcel: 137100850


Addresses:

5401 S ALASKA DR

Inspection Status: Re-inspection required

Inspection History: COT - RSME - Mechanical Final 

Date Description Inspector Results Comments
03/14/2024 COT - RSME - Mechanical Final  Re-inspection required 3/14/24: Caulking missing at toilets, water hammer arrestor missing at (fridge,dishwasher and laundry), anti-tip missing at range, receptacle under sink must be GFCI, laundry room receptacles must be GFCI, insulation needs at hot water line at water heater, properly insulate hose bibs and wrap for UV protection, Arc-fault breaker's missing at multiple locations. No ladder for Mechanical final.
03/26/2024 COT - RSME - Mechanical Final  Re-inspection required 3/14/24: Caulking missing at toilets, water hammer arrestor missing at (fridge,dishwasher and laundry), anti-tip missing at range, receptacle under sink must be GFCI, laundry room receptacles must be GFCI, insulation needs at hot water line at water heater, properly insulate hose bibs and wrap for UV protection, Arc-fault breaker's missing at multiple locations. Sediment trap missing at water heater. No ladder for Mechanical final.
3/26/24: corrections not made per previous notes, A/C unit condensate drainage and gas line not installed, fuses are not installed at A/C unit
03/28/2024 COT - RSME - Mechanical Final  Passed