Permit: TC-RES-1023-08677

Parcel: 112062100


Addresses:

2008 E COPPER ST

Inspection Status: Re-inspection required

Inspection History: COT - RSME - Mechanical Final 

Date Description Inspector Results Comments
03/25/2025 COT - RSME - Mechanical Final  Re-inspection required 25 March 25
1. Laundry, 2 outlets are not GFCI protected.
2. GFCI outlet on the bottom right exterior as you walk into house, has hot and neutral reversed.
3. Water heater is missing T/P discharge piping.
4. Solar breaker on main panel needs to be moved to opposite end of main breaker.
03/28/2025 COT - RSME - Mechanical Final  Passed 3/28/25 passed final corrections made