Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 123120220


Addresses:

2110 N HIGHLAND AV


Inspection Status: Passed

Inspection History: COT - RSEL - Electrical Final 

Permit Number - TC-RES-1022-00202

Inspection Description - COT - RSEL - Electrical Final 

Inspection Status - Passed

Date Description Inspector Results Comments
02/22/2024 COT - RSEL - Electrical Final  Passed Corrections were made. 2/22/2024
11/16/2023 COT - RSEL - Electrical Final  Re-inspection required 11/16/23: missing hammer arrester at dishwasher and clothes washer, receptacle under sink and at laundry room has to be GFCI protected. Missing dead front at sub panel and breakers need to be labled area specific, main panel grounding wire missing. Exterior Vent cover for exhaust fan missing. Patch foundation when plumbing is exposed.