Parcel: 123120220


Addresses:

2110 N HIGHLAND AV


Inspection Status: Passed

Inspection History: RSBU - Building Final 

Permit Number - TC-RES-1022-00202

Inspection Description - RSBU - Building Final 

Inspection Status - Passed

Date Description Inspector Results Comments
02/22/2024 RSBU - Building Final  Passed Corrections were made. 2/22/2024
11/16/2023 RSBU - Building Final  Re-inspection required 11/16/23: missing hammer arrester at dishwasher and clothes washer, receptacle under sink and at laundry room has to be GFCI protected. Missing dead front at sub panel and breakers need to be labled area specific, main panel grounding wire missing. Exterior Vent cover for exhaust fan missing. Patch foundation when plumbing is exposed.