Permit: TC-RES-0926-05424

Parcel: 140442690


Addresses:

6167 E CAMPOLINA TR

Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Plumbing FinalĀ 

Date Description Inspector Results Comments
10/26/2026 COT - RSPL - Plumbing FinalĀ  Re-inspection required 10-26-26 All water pex are required to be insulated in unconditioned spaces* verify that installed tape on exterior piping insulation is UV rated* properly terminate water softener discharge further away from home and further away from footer also please provide air gap 2x the diameter of hose required. Reinspect is required at this time