Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Re-inspection required
Inspection History: COT - RSPL - Plumbing FinalĀ
| Date |
Description |
Inspector |
Results |
Comments |
| 10/26/2026 |
COT - RSPL - Plumbing FinalĀ |
|
Re-inspection required |
10-26-26 All water pex are required to be insulated in unconditioned spaces* verify that installed tape on exterior piping insulation is UV rated* properly terminate water softener discharge further away from home and further away from footer also please provide air gap 2x the diameter of hose required. Reinspect is required at this time |