Inspection Status: Re-inspection required
Inspection History: COT - RSPL - Plumbing Final
| Date |
Description |
Inspector |
Results |
Comments |
| 09/15/2026 |
COT - RSPL - Plumbing Final |
|
Re-inspection required |
9/15/26: insulate hot copper line at water heater, fire foam all penetrations at discontinued oex lines at restrooms, and at top plates above restroom lavatory, seal exterior wall at hose bib and break off screw to vacuum breaker, add a hammer arrestor to dishwasher line. Per IECC C404.4, hot pex lines 1" in diameter and smaller shall be insulated whether in an unconditioned or conditioned space- add accordingly in attic space. |
| 09/16/2026 |
COT - RSPL - Plumbing Final |
|
Passed |
9-16-26 All items have been corrected. Plumbing final approved |