Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: RSPL - Plumbing Progress

Date Description Inspector Results Comments
10/08/2025 RSPL - Plumbing Progress Re-inspection required Provide bracing vertically at water lines and at chance of direction. Add ten mil tape for contact at unistruts. Provide copper lines running to the guest house. Remove pex due to possible physical damage. Insulate water lines once completed. Provide individual lines for plumbing fixtures at water closet and lav at guest house. 10/8/2025
10/09/2025 RSPL - Plumbing Progress Not Ready 10/9/2025 not ready. Workers still working.
10/13/2025 RSPL - Plumbing Progress Passed 10-13-25: approved.