Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/16/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 7-16-26: add straps to DWV & pex lines, cannot use flex for stove exhaust, add backing 9" above rim of tub, DWV not under test, shower liner test is required prior to finals, kitchen and restroom exhausts must extend through roof, missing circuits-not wired per plans. Either install circuits per plans or submit a revision to the city for review, add shot pins to marked areas, frame out mini splits. | |
| 07/17/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 07/17/2026 All corrections made to prior inspection, added 1" foam to 3/4" PEX hot line inside building. |