Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - LCPL - Gas Pressure Test
Permit Number - TC-RES-0924-05552
Inspection Description - COT - LCPL - Gas Pressure Test
Inspection Status - Partial Pass
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/27/2024 | COT - LCPL - Gas Pressure Test | Partial Pass | 8/27/24: partial pass pressure test on 18' run of 1'' black iron piping. Pending water heater run and range. Not easy for south west gas clearance. Shut off valves and sediment traps must be installed at appliance, | |
| 10/07/2024 | COT - LCPL - Gas Pressure Test | Re-inspection required | 8/27/24: partial pass pressure test on 18' run of 1'' black iron piping. Pending water heater run and range. Not ready for south west gas clearance. Shut off valves and sediment traps must be installed at appliance, 10/7/24: not ready not under test, b-vent requires proper clearance from combustibles, must properly terminate. |
|
| 10/11/2024 | COT - LCPL - Gas Pressure Test | Passed | 8/27/24: partial pass pressure test on 18' run of 1'' black iron piping. Pending water heater run and range. Not ready for south west gas clearance. Shut off valves and sediment traps must be installed at appliance, 10/7/24: not ready not under test, b-vent requires proper clearance from combustibles, must properly terminate. 10/11/24: SWG Clearance passed ok for meter tag |