Permit: TC-RES-0924-05501

Parcel: 103110150

Inspection Status: Not Ready

Inspection History: RSBU - Building Final 

Date Description Inspector Results Comments
08/08/2025 RSBU - Building Final  Not Ready
09/15/2025 RSBU - Building Final  Not Ready
11/04/2025 RSBU - Building Final  Not Ready Provide new gfci receptacle in bathroom area/laundry room. Gfci circuit tied into lighting and exhaust fan in laundry room. Provide a self closing 20 min rated door to garage. Provide receptacle between stove and sink. Provide gfci at microwave. Provide WR receptacles at all exterior locations. Exterior receptacle has an open ground. 11/4/2025
11/12/2025 RSBU - Building Final  Passed All corrections were made. 11/12/2025