Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 133326930


Addresses:

9412 E 5TH ST


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-RES-0924-05108

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
01/15/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 1-15-25, over penetrated nailing on sheathing throughout, missing nails on edge at southwest end of exterior wall,truss bracing t2& t3 missing, add firefoam to laundry vent, add blocking to 4 gang box.
01/27/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 1/27/25: All items previously noted on the 1/15/25 inspection have been corrected and are complete. Okay to proceed with installation of insulation and drywall in ceilings and walls.