Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date |
Description |
Inspector |
Results |
Comments |
| 10/28/2024 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Re-inspection required |
Add 2x at receptacle near door on north end to meet 12'. Missing receptacle under switch west wall. Fire foam all top and exterior penetrations. Remove drywall screws from angle stops. Provide 18" of copper at water heater before transitioning to pex. DWV not on test. Add straps to vertical vent lines. Exhaust fan not completed. Stopped inspection other items may occur. 10/28/2024 |
| 10/30/2024 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Passed |
OK to insulate and cover walls. |