Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-0923-08234

Parcel: 12705203B


Addresses:

4858 E 4TH ST

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
11/28/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required Add blocking corner of living room area. Add blocking at verticals ever 10'. Add two king studs and straps at SGD. Move smoke detectors over 6" from top and side walls. Add anchor bolts at edges of bottom plates and at 48". Provide 18" of copper before transitioning to pex at water heater. Add three way switch at living room. Add exhaust fan is laundry room. 11/28/2023
12/01/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 12/1/23: all corrections made