Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Not Ready

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
04/09/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready
04/15/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required Partial approval DWV is not under test. One section of ductwork is not R eight caulk all windows in for stucco wrap, fire foam all plate penetrations
4/15/24: seal all penetrations through top plate, R-6 flex needs to be replaced with R-8, Wye at entrance needs to be insulated, nail plates missing at plumbing walls, exhaust fan at laundry rooms missing wire, exhaust at kitchen and laundry making contact work copper piping.
04/16/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Partial Pass Partial approval DWV is not under test. One section of ductwork is not R eight caulk all windows in for stucco wrap, fire foam all plate penetrations
4/15/24: seal all penetrations through top plate, R-6 flex needs to be replaced with R-8, Wye at entrance needs to be insulated, nail plates missing at plumbing walls, exhaust fan at laundry rooms missing wire, exhaust at kitchen and laundry making contact work copper piping.
4/16/24: corrections made ok to proceed.
09/03/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed