Inspection Status: Passed
Inspection History: COT - RSPL - Plumbing Final
| Date |
Description |
Inspector |
Results |
Comments |
| 01/10/2024 |
COT - RSPL - Plumbing Final |
|
Passed |
|
| 12/05/2023 |
COT - RSPL - Plumbing Final |
|
Re-inspection required |
12/5/23: GFCI receptacles missing in multiple locations within 6' of water source, receptacles at island not per code, water hammer arrestor missing at (dishwasher,fridge,washer), disposal needs proper drainage, T&P valve drain missing at water heater, outdoor receptacles missing, smoke alarms are not interconnected. A/C unit requires p-trap, A/C service receptacle has no power and requires WR receptacle in a bubble cover. Other times may be added. |
| 12/08/2023 |
COT - RSPL - Plumbing Final |
|
Re-inspection required |
12/08/2023. Failed. Work not completed. |