Permit: TC-RES-0923-08070

Parcel: 130181180


Addresses:

2113 S IRVING AV

Inspection Status: Re-inspection required

Inspection History: RSBU - Building Final 

Date Description Inspector Results Comments
01/08/2024 RSBU - Building Final  Re-inspection required 1/8/24: metal or concrete clean out box needed at front yard . Both house and casita need heat strip labeled for circuit breaker size. Receptacles on both roofs not GFCI protected.
01/10/2024 RSBU - Building Final  Passed
12/05/2023 RSBU - Building Final  Re-inspection required 12/5/23:
Main house:Cleanout at front driveway must be metal clean out and must be protected, footing must be excavated to show proper footing,A/C jumper needs to be insulated, missing facia board, no bedroom arc fault at panel, properly label panel, needs 2 kitchen circuits, receptacle at kitchen island not per code,caulking underneath toilets, open ground at bedroom receptacle,framing not per plan, GFCI receptacles missing in multiple locations within 6' of water source, receptacles at island not per code, water hammer arrestor missing at (dishwasher,fridge,washer), disposal needs proper drainage, T&P valve drain missing at water heater, outdoor receptacles missing, smoke alarms are not interconnected. A/C unit requires p-trap, A/C service receptacle has no power and requires WR receptacle in a bubble cover. Other times may be added.

Casita: UV coat abs on roof, bubble cover missing at exterior receptacles, properly insulate spiral duct, needs 2 circuits at kitchen, Arc fault at panel missing where required, windows at casita not per plan, framing not per plan. GFCI receptacles missing in multiple locations within 6' of water source, receptacles at island not per code, water hammer arrestor missing at (dishwasher,fridge,washer), disposal needs proper drainage, T&P valve drain missing at water heater, outdoor receptacles missing, smoke alarms are not interconnected. A/C unit requires p-trap, A/C service receptacle has no power and requires WR receptacle in a bubble cover. Other times may be added.

As-built required and letters from R.O.C electric and plumbing stating that all work completed meets or exceeds 2018 IRC requirements.
12/08/2023 RSBU - Building Final  Re-inspection required 12/08/2023. Failed. Work not completed